BIOMETRY COURSE 2. Biometry Measurements Welcome to Biometry Emma - - PowerPoint PPT Presentation

▶
biometry course
SMART_READER_LITE
LIVE PREVIEW

BIOMETRY COURSE 2. Biometry Measurements Welcome to Biometry Emma - - PowerPoint PPT Presentation

BIOMETRY COURSE 2. Biometry Measurements Welcome to Biometry Emma Deighan Trainer in Ophthalmology for 20 Years Please ask questions! Email emma@medsalesacademy.co.uk www.medsalesacademy.co.uk Today we will learn How to


slide-1
SLIDE 1

BIOMETRY COURSE

  • 2. Biometry Measurements
slide-2
SLIDE 2

www.medsalesacademy.co.uk

Welcome to Biometry

๏

Emma Deighan

๏

Trainer in Ophthalmology for 20 Years

๏

Please ask questions!

๏

Email emma@medsalesacademy.co.uk

slide-3
SLIDE 3

www.medsalesacademy.co.uk

Today we will learn

๏

How to measure Biometry

๏

What measurements are needed

๏

How we see

๏

How to read the measurements and apply to patients

๏

Understanding the Biometry Report

slide-4
SLIDE 4

www.medsalesacademy.co.uk

Biometry

Relates to Measurements required for calculation

๏ Axial Length ๏ K reading ๏ Anterior Chamber Depth ๏ White to White ๏ Lens thickness ๏ Central Corneal Thickness

slide-5
SLIDE 5

www.medsalesacademy.co.uk

Ways to Measure

IOL Master Lenstar Pentacam AXL

slide-6
SLIDE 6

www.medsalesacademy.co.uk

Axial Length

๏

Optical or Ultrasound?

๏

Most biometry is done on an optical system

๏

If the cataract is too dense you may need to use Ultrasound

slide-7
SLIDE 7

www.medsalesacademy.co.uk

Optical Biometry

slide-8
SLIDE 8

www.medsalesacademy.co.uk

Signal to Noise Ratio

slide-9
SLIDE 9

www.medsalesacademy.co.uk

Tips

๏

Make sure patient is comfortable and straight in the chin rest

๏

For Axial Length, you can move the image around to try and find a way through a cataract

๏

Like trying to peak through a dirty window

slide-10
SLIDE 10

www.medsalesacademy.co.uk

Moving the spot

slide-11
SLIDE 11

www.medsalesacademy.co.uk

Moving the spot

slide-12
SLIDE 12

www.medsalesacademy.co.uk

Moving the spot

slide-13
SLIDE 13

www.medsalesacademy.co.uk

Moving the spot

slide-14
SLIDE 14

www.medsalesacademy.co.uk

Moving the spot

slide-15
SLIDE 15

www.medsalesacademy.co.uk

Moving the spot

slide-16
SLIDE 16

www.medsalesacademy.co.uk

Changing Spot size

slide-17
SLIDE 17

www.medsalesacademy.co.uk

Ultrasound

slide-18
SLIDE 18

www.medsalesacademy.co.uk

Ultrasound Tips

๏

Use anaesthetic

๏

Align probe perpendicular to cornea

๏

Don’t indent

slide-19
SLIDE 19

www.medsalesacademy.co.uk

Question Time

slide-20
SLIDE 20

www.medsalesacademy.co.uk

Keratometry

๏

Shape of cornea

๏

K1 & K2

๏

Irregular readings??

slide-21
SLIDE 21

www.medsalesacademy.co.uk

K-Readings

๏

Imagine a Teaspoon

๏

One curve is flatter (K1)

๏

One curve is steeper (K2)

๏

The Handle is the flat axis

๏

Difference between K1 and K2 is corneal astigmatism

slide-22
SLIDE 22

www.medsalesacademy.co.uk

K-Readings

๏

K1 Flat

๏

K2 Steep

๏

Some corneas are irregular and K reading vary across the surface.

slide-23
SLIDE 23

www.medsalesacademy.co.uk

ACD

๏

Can be measured

๏

Anterior epithelium

๏

Or Posterior Endothelium

slide-24
SLIDE 24

www.medsalesacademy.co.uk

White to White

slide-25
SLIDE 25

www.medsalesacademy.co.uk

White to White

๏

White to White

๏

Angle to Angle

๏

Sulcus to Sulcus

slide-26
SLIDE 26

www.medsalesacademy.co.uk

Question Time

slide-27
SLIDE 27

www.medsalesacademy.co.uk

Average Dimensions

Measurement Average Normal Range K Reading 43 Ds 40-47 Ds Axial Length 23.5mm 22-26mm Pupil Size 5.5mm 3-9mm White to White 11.5mm 10-13mm CCT 555µm 500-600µm ACD 3.25mm 3.00-3.75mm

slide-28
SLIDE 28

www.medsalesacademy.co.uk

Average Dimensions

Measurement Average Normal Range IOP 15-16 mmhg 10-20 mmhg Lens Thickness 4mm Thickens with age Retinal Thickness 300 microns Anterior Chamber Angle Varies 20-350

slide-29
SLIDE 29

www.medsalesacademy.co.uk

Myope

๏

What is the Axial Length ?

  • Over 23 Under 23

๏

K Reading?

  • Over 42 under 43

๏

ACD

  • Over 3.25 under 3.25

๏

White to White

  • Over 11.5 under 11.5
slide-30
SLIDE 30

www.medsalesacademy.co.uk

Hyperope

๏

What is the Axial Length ?

  • Over 23 Under 23

๏

K Reading?

  • Over 42 under 43

๏

ACD

  • Over 3.25 under 3.25

๏

White to White

  • Over 11.5 under 11.5
slide-31
SLIDE 31

www.medsalesacademy.co.uk

What is the IOL Power

๏ Myopes ๏ Over or under 23 ๏ Hyperopes ๏ Over or under 23

slide-32
SLIDE 32

www.medsalesacademy.co.uk

Biometry Printout

slide-33
SLIDE 33

www.medsalesacademy.co.uk

Lenstar Printout

slide-34
SLIDE 34

www.medsalesacademy.co.uk

Question Time

slide-35
SLIDE 35

www.medsalesacademy.co.uk

Review the Printout

๏

We will go through the IOL Master Printout so you can understand where the figures come from.

๏

Please do this with biometry reports you find at work

๏

I’ll happily go through them with you.

๏

Remember to hide the patient’s details

slide-36
SLIDE 36

www.medsalesacademy.co.uk

Measurement

slide-37
SLIDE 37

www.medsalesacademy.co.uk

Calculation

slide-38
SLIDE 38

www.medsalesacademy.co.uk

Today we have learnt

๏

How to measure Biometry

๏

What measurements are needed

๏

How we see

๏

How to read the measurements and apply to patients

๏

Understanding the Biometry Report

slide-39
SLIDE 39

www.medsalesacademy.co.uk

Thank you

๏

For more information see www.nice.org.uk/guidance/ng77

๏

We hope this session was useful

๏

Please send us your questions

๏

emma@medsalesacademy.co.uk

๏

See you on the next module

  • Diagnostic Devices