ENDURA Dual Application in LIBEHEER 994 0 Abstract 1. ENDURA Dual - - PowerPoint PPT Presentation

endura dual application in libeheer 994
SMART_READER_LITE
LIVE PREVIEW

ENDURA Dual Application in LIBEHEER 994 0 Abstract 1. ENDURA Dual - - PowerPoint PPT Presentation

ENDURA Dual Application in LIBEHEER 994 0 Abstract 1. ENDURA Dual and AR500 plate were used as test pieces 2. The wear plates were welded at the same level but diffrent sides of the bucket where most sliding abrasion occurs. 3. The bucket


slide-1
SLIDE 1

ENDURA Dual Application in LIBEHEER 994

slide-2
SLIDE 2

Abstract

  • 1. ENDURA Dual and AR500 plate were used as test pieces
  • 2. The wear plates were welded at the same level but diffrent sides of the

bucket where most sliding abrasion occurs.

  • 3. The bucket capacity of LIBBEHIER 994 is 18 m3. The average working time is

19 hours every day , and there are 7 working days every week

  • 4. By the end of the third evaluation (2013/3/29) the test plates had been on the

bucket for more then 551 hrs of service.

2

slide-3
SLIDE 3

Welding

1. the surrounding temperature is -14 deg. Celcius. 2. the welding material is general Lincoln 7018. 3. welding process is SMAW.

3

slide-4
SLIDE 4

Thickness measure

AR500 (2013/3/1) ENDURA Dual (2013/3/1)

4

slide-5
SLIDE 5

Thickness measure

AR500 (2013/3/9) ENDURA Dual (2013/3/9)

5

slide-6
SLIDE 6

Thickness measure

AR500 (2013/3/21) ENDURA Dual (2013/3/21)

6

slide-7
SLIDE 7

7

Anti-Abrasion Evaluation

ENDURA Dual Compared with AR500 Time (h) Thickness (mm) 171 399 551 ENDURA D u a l 30 29.5 28 26.5 AR500 30 26.3 23 15

ENDURA Dual AR500 Thickness (mm) Service Time (h)

slide-8
SLIDE 8

Conclusion

  • 1. In low temperature, ENDURA Dual has excellent welding performance.
  • 2. The projected service life of ENDURA Dual is 7.58 months compared to

AR500 which is 3.63 months.

  • 3. The service life of ENDURA Dual is projected to be more than double that
  • f AR500 plate.
  • 4. ENDURA Dual’s homogeneous microstructure guarantees

the abrasion rate is uniform and consistent during the application.

  • 5. Even in low temperatures with continuous abrasion, the wear surface

ENDURA Dual is smooth and even.

  • 6. This illustrates exceptional anti-abrasion characteristics vs. AR500 which

exhibited significant pitting, gouging and serious wear on the surface, as well as cracking thru the body of the plate.

8

slide-9
SLIDE 9

thanks for your attention, any questions?

9