I. Table of Contents 2 I. Table of Contents - - PDF document

i table of contents
SMART_READER_LITE
LIVE PREVIEW

I. Table of Contents 2 I. Table of Contents - - PDF document

NanoGen 3 Smart HV Pulses Generator Technical Presentation Author : Fabrice BOUTERIGE Date : 26/03/2018 Version 1.0 RLC- Richard Lepan Consulting SARL- capital 72300 -SIRET 539 087 098 00023- TVA FR94539087098- APE 7112B 7 Rue du Pr La


slide-1
SLIDE 1

NanoGen 3

Smart HV Pulses Generator

Technical Presentation

Author : Fabrice BOUTERIGE Date : 26/03/2018 Version 1.0

RLC- Richard Lepan Consulting SARL- capital 72300€-SIRET 539 087 098 00023- TVA FR94539087098- APE 7112B 7 Rue du Pré La Reine 63100 CLERMONT-FERRAND Tel :04 73 2626 36 - Fax : 04 73 25 94 23

slide-2
SLIDE 2

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

2

  • I. Table of Contents
  • I. Table of Contents .............................................................................................................................

2

  • II. NanoGen3 Presentation

................................................................................................................... 3 II.1. Main Features ........................................................................................................................................ 3 II.2. Internal Wiring ....................................................................................................................................... 3 II.3. Description of Front Panel ...................................................................................................................... 4 II.4. Description of Rear Panel ...................................................................................................................... 4 II.5. Global Wiring ......................................................................................................................................... 5

  • III. CPU Board ......................................................................................................................................

6

  • IV. HV Power Switch Board ..................................................................................................................

7

  • V. Oscillograms ...................................................................................................................................

8

  • VI. NanoGen 3 HMI

.............................................................................................................................. 9

  • VII. Maximum Power Limitation.........................................................................................................

10

slide-3
SLIDE 3

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

3

  • II. NanoGen3 Presentation

II.1. Main Features

Voltage Adjust 0-30 kV Pulse Frequency 1Hz - 100 kHz Pulse Width 250 ns - 25µs Duty cycle 0.1% - 50% Output Current max 50A at Fmax = 1 kHz, pulse width max = 10µs

  • r duty cycle max = 1 %

II.2. Internal Wiring

Switch Driver CPU Box 180V AuxSwitch Supply 15V AuxSwitch Supply

slide-4
SLIDE 4

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

4

II.3. Description of Front Panel

  • Switch « EMERGENCY STOP »
  • Switch « POWER ON / OFF » and LED « POWER ON »
  • Switch « SWITCH ENABLE » : this switch enables or disables the HV Pulses Output
  • Green LED « SWITCH ENABLE » : LED is on if the HV Pulses Output is enabled
  • Red LED « SWITCH DISABLE / FAULT » : LED is on if the HV switch is disabled or in fault state

II.4. Description of Rear Panel

  • Input Connector « HVPS IN » : HV Supply Input (30kV max)
  • Output Connector « HV PULSE OUT » : HV Pulse Outputs
  • GND Connector « GND STAR » :HV Ground
  • SUBD9 Connector « COMPC RS232 » :RS232 Communication with Optical Fiber adaptator
  • SUBD15 Connector « COM HVPS ANALOG » :HV Power Supply Analog Control Interface
  • BNC Connector « GENER INPUT » :Input from External Generator
  • BNC Connector « SYNCHRO OUTPUT » :Synchronization Output
slide-5
SLIDE 5

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

5

II.5. Global Wiring

HV Supply NanoGen 3 Computer Faraday Cage HV GND SHIELD PULSES OUT POWER RETURN RS232

Optical fiberlink

ANALOG COM WARNING ! POWER RETURN must be connected to GND STAR

slide-6
SLIDE 6

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

6

  • III. CPU Board

The CPU Board:

  • manages the RS232 communication with the PC
  • controls the external HV Power supply
  • generates the PWM or BURST signal to control the HV Power Switch

220V PC RS232 HVPS Management

RS232 Driver

HVPS INTERFACE

Front Panel Control Rear Panel EXT Control

EXT GENERATOR Power Supply Management

Control Unit Processor

Microcontroller 5V Pulses Output Signal

FRONT PANEL Control Voltage Adaptation Interface

Programming Voltage Output Enable Control Voltage Monitoring

SYNCHRO

Rear Panel Synchro Generation

Adaptation Interface Analog Isolation Analog Isolation HV Power Supply INTERFACE Enable HV Supply Monitor Voltage Numeric Isolation

slide-7
SLIDE 7

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

7

  • IV. HV Power Switch Board

The HV Power Swicth Board is based on the BELHKE fast high voltage transistor switch HTS 301-10-GSM.

HV Swicth Supply 15 VDC and 180VDC Current Limiter

5V Pulses Input Signal

HV PULSES OUT Current Limiter Switch Driver + HV Suplly Input Power Management

High-Speed HV Switch

Front Panel Interface

SWITCH DISABLE / FAULT SWITCH ENABLE
slide-8
SLIDE 8

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

8

  • V. Oscillograms

HV Output Pulses

slide-9
SLIDE 9

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

9

  • VI. NanoGen 3 HMI

The NanoGen3 is controlled by a « Human-Machine Interface », developed by RLC, that can be installed on any PC or on a laptop. The NanoGen 3 HMI controls :

  • The external HV Power Supply

Output Voltage / ON / OFF

  • The PWM or BURST Output Pulses parameters

Pulse Frequency / Pulse duration… Optical fiber forRS232 link Control the NanoGen3 with the HMI NanoGen 3

slide-10
SLIDE 10

Technical Presentation|RLC, CLERMONT-FERRAND NanoGen3 : Smart HV Pulses Generator (V1.0)

10

  • VII. Maximum Power Limitation

The yelow line represents the maximum power limitation. The safety area is under this line. Thanks to the new software, the user can not go beyond the maximum power limits.