Magnetic Distortion Distortion of of Magnetic HPD Images HPD - PowerPoint PPT Presentation
Magnetic Distortion Distortion of of Magnetic HPD Images HPD Images smund Skjveland smund Skjveland The LHCb LHCb experiment experiment The The LHCb LHCb experiment experiment The Observe CP violation in decays of heavy
Magnetic Distortion Distortion of of Magnetic HPD Images HPD Images Åsmund Skjæveland Åsmund Skjæveland
The LHCb LHCb experiment experiment The
The LHCb LHCb experiment experiment The • Observe CP violation in decays of heavy • Observe CP violation in decays of heavy hadrons produced in p p- -p p collisions collisions hadrons produced in – Need accurate particle identification: Need accurate particle identification: – • Tracking stations track particles with high precision • Tracking stations track particles with high precision • Magnet deflects track • ➨ momentum Magnet deflects track ➨ momentum and and charge charge velocity ➨ ➨ combine • RICH • RICH measure measure velocity combine with with momentum to to find find mass mass momentum
The RICH RICH detectors detectors in in LHCb LHCb The
RICH detectors RICH detectors • Measures velocities via • Measures velocities via Č erenkov Č erenkov radiation radiation ➨ high resolution – Uses Hybrid Photon Detectors Uses Hybrid Photon Detectors ➨ high resolution – – Combine images from many Combine images from many HPDs HPDs to find to find – Č erenkov circles circles Č erenkov
RICH detectors RICH detectors • Measures velocities via • Measures velocities via Cherenkov Cherenkov radiation radiation ➨ high resolution – Uses Hybrid Photon Detectors Uses Hybrid Photon Detectors ➨ high resolution – – Combine images from many Combine images from many HPDs HPDs to find to find – Cherenkov circles circles Cherenkov
Hybrid Photon Photon Detector Detector Hybrid • 37.5 mm radius • 37.5 mm radius • 110 mm • 110 mm long long • Quartz • Quartz optical optical window window • Resolution • Resolution 256x 256x32 32 pixels pixels • Photoelectron • Photoelectron optics optics ➨ sensitive to ➨ sensitive to magnetic fi elds fi elds magnetic
Pixel Hybrid Hybrid Photon Photon Detector Detector Pixel
Problem Problem • RICH1 is close to spectrometer magnet • RICH1 is close to spectrometer magnet • HPDs • HPDs will be measurably affected by small will be measurably affected by small fi elds ➨ ➨ image is magnetic fi elds image is distorted distorted magnetic – Reconstruction Reconstruction of of circle circle requires requires undisturbed undisturbed – images: Photon hits must be measured very images: Photon hits must be measured very accurately accurately – If perturbation is large, data will be pushed If perturbation is large, data will be pushed – ➨ uncorrectable off image chip ➨ uncorrectable data loss data loss off image chip
Magnetic Shielding Magnetic Shielding • RICHes • RICHes enclosed in enclosed in iron box— —internal internal iron box fi eld eld reduced to reduced to fi MuMetal-shield max. 25 G (RICH1) max. 25 G (RICH1) and 10 G (RICH2) and 10 G (RICH2) • MuMetal • MuMetal shield shield around each HPD around each HPD further reduces further reduces magnetic fi fi eld eld magnetic
Experiment setup Experiment setup Filter HPD Coils Projector
Setup Setup • Standard projector connected to laptop • Standard projector connected to laptop • Dense optical • Dense optical fi lters fi lters • HPD tube • HPD tube • Read • Read- -out electronics out electronics
Calibration Calibration • Projected image much larger than HPD • Projected image much larger than HPD • Find HPD by sweeping horizontal and • Find HPD by sweeping horizontal and vertical lines across the screen vertical lines across the screen • Fine • Fine- -tune with line patterns tune with line patterns
Calibration Calibration
Calibration Calibration
Calibration Calibration
Data taking Data taking • Illuminate HPD with a • Illuminate HPD with a de fi ned pattern pattern de fi ned • Vary magnetic • Vary magnetic fi eld fi eld • Record HPD image • Record HPD image
Observations for axial fi elds fi elds Observations for axial 20 G 0 G 30 G 50 G
Observations Observations • Small but clear • Small but clear background background – thermal electrons thermal electrons – – ion feedback ion feedback – • Image is rotated • Image is rotated • Image is enlarged • Image is enlarged • Image center is • Image center is slightly displaced slightly displaced
Conclusion Conclusion • Entire image on chip: • Entire image on chip: No data loss No data loss – Reconstruction of undisturbed image probably Reconstruction of undisturbed image probably – possible possible
To Be Done To Be Done • Make and test other test patterns • Make and test other test patterns • Measure other field configurations • Measure other field configurations • Make and test image correction algorithm • Make and test image correction algorithm • Publish • Publish • Have a beer • Have a beer