PXD Resolution in Large Occupancies
- Z. Drásal , K. Prothmann
Charles University Prague MPI Munich
PXD Resolution in Large Occupancies Z. Drsal , K. Prothmann - - PowerPoint PPT Presentation
PXD Resolution in Large Occupancies Z. Drsal , K. Prothmann Charles University Prague MPI Munich Outline ILC Software (Marlin) new implementation of background simulations + added effects of ganged pixels in simulation
Charles University Prague MPI Munich
29th Sep 2010 2 5th International Workshop on DEPFET Detectors and Applications
– MergeBackground: new Marlin processor merging signal Mokka hits with background
hits (Belle II QED background) into common ILC collection (PXD, SVD, CDC)
– SiPxlDigi: Marlin processor improved with simulation of effects of ganged pixels
– Resolution studies – Efficiency studies (resp. inefficiency due to high background) – Impact parameter studies (not complete yet)
29th Sep 2010 3 5th International Workshop on DEPFET Detectors and Applications
Reconstruction Simulation
Mokka
(Geant4)
GEAR (XML)
Geometry information
LCIO (persistency data model) Pythia
Generator
ROOT LCIO
LCCD
HEPEvt (ASCII)
Generated events
Marlin
MaterialDB MergeBackground Digitization
...
Optimization
ILC Software Scheme
– merges together:
background) → overlay several *.slcio files to get required (expected)
PXD Signal Hits Background Hits _0 Background Hits _1 Background Hits _2 Background Hits _3 PXD Merged Hits
29th Sep 2010 4 5th International Workshop on DEPFET Detectors and Applications
– 0 % (no background) – 5 – 6 % – 10 – 12 % – 15 – 18 %
read-out by common drain; 0 – 400 row, 1 – 401 row, 2 – 402, …):
– resolutions in R-Phi & Z, resp. their degradation in “harsh” background – TrackerHit efficiency (hit is OK if found by clustering algorithm & if major contribution to the
signal is from simulated SimTrackerHit) → nonefficiency degrades resolution: hit found, but not coming from original particle (background effect – hits overlayed) or not found at all (signal/noise too low → clustering doesn't find it)
– impact parameter resolution & track efficiency
29th Sep 2010 5 5th International Workshop on DEPFET Detectors and Applications
t & 2n d layer – noGanged x Right: 1s t & 2n d layer – ganged
29th Sep 2010 6 5th International Workshop on DEPFET Detectors and Applications
t & 2n d layer – noGanged x Right: 1s t & 2n d layer – ganged
29th Sep 2010 7 5th International Workshop on DEPFET Detectors and Applications
t & 2n d layer – noGanged x Right: 1s t & 2n d layer – ganged
29th Sep 2010 8 5th International Workshop on DEPFET Detectors and Applications
29th Sep 2010 9 5th International Workshop on DEPFET Detectors and Applications
P [GeV] P [GeV] 500 MeV Muons 2.5 GeV Muons
0.5 GeV Eff. 0.5 GeV Purity 2.5 GeV Eff. 0.5 GeV Purity ganged 98.15 99.46 unganged 98.19 99.48 Error: +- 1%
29th Sep 2010 10 5th International Workshop on DEPFET Detectors and Applications
Number of tracks Number of tracks Number of tracks Number of tracks 500 MeV Muons Ganged pixels 500 MeV Muons Unganged pixels 2.5 GeV Muons Ganged pixels 2.5 GeV Muons Unganged pixels
29th Sep 2010 11 5th International Workshop on DEPFET Detectors and Applications
500 MeV Muons Ganged pixels 500 MeV Muons Unganged pixels Z0 [mm] Z0 [mm] Pseudo momentum [GeV] Pseudo momentum [GeV]
29th Sep 2010 12 5th International Workshop on DEPFET Detectors and Applications
→ necessary to complete the study for 1%, resp. 2% QED background
29th Sep 2010 13 5th International Workshop on DEPFET Detectors and Applications