Signal Acquisition from Piezoelectric Transducers for - - PowerPoint PPT Presentation

signal acquisition from piezoelectric transducers for
SMART_READER_LITE
LIVE PREVIEW

Signal Acquisition from Piezoelectric Transducers for - - PowerPoint PPT Presentation

4th International Electronic Conference on Sensors and Applications 15-30 November 2017 Signal Acquisition from Piezoelectric Transducers for Impedance-Based Damage Detection Danilo Ecidir Budoya and Fabricio Guimares Baptista So Paulo


slide-1
SLIDE 1

Signal Acquisition from Piezoelectric Transducers for Impedance-Based Damage Detection

Danilo Ecidir Budoya and Fabricio Guimarães Baptista São Paulo State University (UNESP) School of Engineering, Bauru Department of Electrical Engineering Laboratory of Transducers and Data Acquisition

  • Av. Eng. Luiz Edmundo Corrijo Coube, 14-01, Bauru-SP, 17033-360, Brazil

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-2
SLIDE 2

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

2

Outline

  • Structural Health Monitoring (SHM)
  • Electromechanical Impedance (EMI) Method
  • Damage Detection
  • Measurement Systems
  • Piezoelectric Transducers
  • Experimental Setup
  • Results
  • Conclusions

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-3
SLIDE 3

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

3

Structural Health Monitoring (SHM)

  • Monitor the presence of structural damage;
  • Applications: airplanes, pipelines, dams, bridges, among others.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-4
SLIDE 4

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

4

Structural Health Monitoring (SHM)

Damages

  • Cracks;
  • Corrosions;
  • Fatigue;
  • Delaminations.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-5
SLIDE 5

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

5

Structural Health Monitoring (SHM)

BENEFITS

IMPROVED SAFETY REDUCTION OF MAINTENANCE COSTS INCREASED LIFETIME

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-6
SLIDE 6

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

6

Structural Health Monitoring (SHM)

There are several non-invasive techniques, known as Non-Destructive Testing (NDT), suitable for SHM systems applications:

  • Acoustic Emission;
  • Comparative Vacuum;
  • Eddy current;
  • Lamb waves;
  • Electromechanical Impedance (EMI).

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-7
SLIDE 7

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

7

Electromechanical Impedance (EMI) Method

The Electromechanical Impedance (EMI) method stands out from the

  • ther techniques for its simple methodology and the use of small and

low-cost piezoelectric transducers.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-8
SLIDE 8

1 2 31 11 33

( ) 1 ( ) 1 2 ( ) ( )

S E E T S P

d Z f Z f j fC Z f Z f s π ε

= − +

     

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

8

Electromechanical Impedance (EMI) Method

Principle

ZE(f) - Electrical impedance of the piezoelectric transducer ZS(f) - Mechanical impedance of the monitored structure

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-9
SLIDE 9

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

9

Damage Detection

Damage Indices

  • The damage indices are calculated using two electrical impedance

signatures (module, real part or imaginary part) of the piezoelectric transducer: one referring to the structure without damage (baseline) and the other referring to the structure in a possible damaged condition;

  • For this work, the index used for the characterization of damage is

the correlation coefficient deviation metric (CCDM), that was calculated using the real part of the electrical impedance.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-10
SLIDE 10

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

10

Damage Detection

Correlation Coefficient Deviation Metric (CCDM)

, , , , 2 2 , , , ,

( ) ( ) 1 ( ) ( )

F I F F I I

f E H E D E H E D k f f f E H E D E H E D k f k f

Z k Z Z k Z CCDM Z k Z Z k Z

= = =

− − = − − −

               

∑ ∑ ∑

Structure Condition Healthy Condition Damaged Condition

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-11
SLIDE 11

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

11

Measurement Systems

  • Since the detection and quantization of damages are performed by

comparing two electrical impedance signatures, it is essential that the measurement system be of high precision to enable the correct diagnosis of the monitored structure;

  • Thus, two measurement systems that use different methods of signal

acquisition of the piezoelectric transducers are compared in this work in terms of precision of the measurements and sensibility to the presence of damage. The main difference between these systems is the type of excitation signal.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-12
SLIDE 12

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

12

Measurement Systems

Excitation Signals

  • Chirp dynamic signal

A single signal containing all the frequencies desired for analysis;

  • Sine wave signals

Composed of various sinusoidal signals to encompass all the frequencies desired for analysis

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-13
SLIDE 13

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

13

Piezoelectric Transducers

Piezoelectric Diaphragm – “Buzzer”

Dimensions

  • Active element

Diameter: 14 mm; Thickness: 0.22 mm.

  • Brass plate

Diameter: 20 mm; Thickness: 0.20 mm. Manufactured by Murata Manufacturing 7BB-20-6

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-14
SLIDE 14

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

14

Experimental Setup

Materials

  • DAQ NI-USB-6361;
  • Aluminum bar of 790 mm x 75 mm x 3 mm;
  • Piezoelectric diaphragm 7BB-20-6 type;
  • Steel nut of 8 mm x 14 mm (Large Damage);
  • Steel sphere of 1 mm in diameter (Small Damage).

Experiments

  • Experiment 1: Evaluate repeatability and precision
  • f the measurements of each system;
  • Experiment 2: Evaluate the sensitivity of each

system to detect different damages.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-15
SLIDE 15

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

15

Results

Experiment 1

Twenty measurements with each measuring system around a resonant peak of the monitored bar, between 44 kHz and 44.3 kHz.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-16
SLIDE 16

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

16

Results

Experiment 1

Standard deviation, point-to-point, of the twenty measurements taken with the two measurement systems.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-17
SLIDE 17

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

17

Results

Experiment 1

  • The method with sine wave excitation signals presented better precision than the

chirp type excitation signal method for all points analyzed;

  • The largest difference between the standard deviations of the systems occurred at

the frequency of 44020 Hz, with the deviation of the system with chirp signal being 58.34 times greater than the deviation of the system with sine wave signals;

  • The smallest difference between the standard deviations was in the frequency of

44190 Hz, being the deviation of the system with chirp signal 2.49 times greater than that of the sine wave system

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-18
SLIDE 18

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

18

Results

Experiment 2

Normalized CCDM indices calculated for a sub-band of 10 kHz, between 40 kHz and 50 kHz, with the bar undamaged and with the two different damages for the two measurement systems.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-19
SLIDE 19

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

19

Results

Experiment 2

  • The precision of the two methods can be further compared by analyzing the

indices obtained for the healthy structure. Since the data were normalized, the indices were expected to be unit value.

  • Regardless the damage size, the method with sine wave signals is more sensitive

to damage than the system with chirp signal;

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-20
SLIDE 20

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

20

Conclusions

  • Both acquisition methods are able to detect damage and, therefore, are suitable for

impedance-based SHM applications;

  • The method using sine waves showed higher precision and sensitivity to the

presence of damage in the monitored structure;

  • These results should be considered in the development of SHM systems, since a

more precise and sensitive method can detect incipient structural damage and avoid false-positive diagnoses.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-21
SLIDE 21

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

21

Acknowledgments

The authors are grateful to FAPESP – Sao Paulo Research Foundation (grant 2015/23272-1, 2015/02500-6) for the financial support.

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

slide-22
SLIDE 22

4th International Electronic Conference on Sensors and Applications

15-30 November 2017

22

Thank you!

4TH INTERNATIONAL ELECTRONIC CONFERENCE ON SENSORS AND APPLICATIONS

Danilo Ecidir Budoya danilo.budoya@feb.unesp.br Fabricio Guimarães Baptista* fabriciogb@feb.unesp.br

* Correspondence: fabriciogb@feb.unesp.br; Tel.: +55 (14) 3103-6115 - Ramal 6764

São Paulo State University (UNESP) School of Engineering, Bauru Department of Electrical Engineering Laboratory of Transducers and Data Acquisition

  • Av. Eng. Luiz Edmundo Corrijo Coube, 14-01, Bauru-SP, 17033-360, Brazil