THIS PROPERTY IS NOT WITHIN A SPECIAL FLOOD HAZARD AREA AND NOT - - PowerPoint PPT Presentation

this property is not within a special flood hazard area
SMART_READER_LITE
LIVE PREVIEW

THIS PROPERTY IS NOT WITHIN A SPECIAL FLOOD HAZARD AREA AND NOT - - PowerPoint PPT Presentation

GENERAL CONSTRUCTION NOTES BUILDING DEPARTMENT NOTES TENANT SAFETY NOTES CONT. SMOKE DETECTOR 2'-6" SPECIAL 5'-0" MIN METAL THREADED INSERTS REMOVABLE TO RECEIVE SCREWS 3. INSTALL ALL BARRICADES, SIGNS SCAFFOLDING, TEMPORARY


slide-1
SLIDE 1

GENERAL INFORMATION

36" MIN. 18" 48" MIN. 66" MIN. 36" MIN. 18" 48" MIN. 56" MIN. 18" 60" MIN. 56" MIN. 33-36" 12" 12" 36" MIN. 36" MIN. 12" 54" MIN. 19" 33-36" 17-19" 36" 9"MIN. 27" MIN. 29" MIN. 34" MAX. 40" MAX. 30" 17" 4' 19" MAX. 30" 60" MIN. 48" MIN. 60" MIN. 75" MIN. 30" MIN. 15" 24" 33-36" 12" MAX. 12" MIN. 24" 33-36" 12" MAX. 9" 2'-6" 2'-4" MIN. MIN. MIN. MIN. MIN. MAX.

20

CLEAR FLOOR SPACE AT WATER CLOSETS

SCALE: 1/8" = 1'-0"

21

SCALE: 1/8" = 1'-0"

GRAB BARS AT WATER CLOSETS

23

SCALE: 1/8" = 1'-0"

LAVATORY CLEARANCES

22

SCALE: 1/8" = 1'-0"

MIN. MIN. CLEAR FLOOR SPACE

LAVATORY CLEARANCES

MIN. SEAT HEAD FOOT BACK SEAT SEAT

10

SCALE: 1/8" = 1'-0"

MIN. CONTROL AREA MIN. MAX. FOOT BACK HEAD MIN. CONTROL AREA FOOT BACK HEAD

CLEAR FLOOR SPACE AT BATHTUBS

11

SCALE: 1/8" = 1'-0"

GRAB BARS AT BATHTUBS WITH SEAT IN TUB

12

SCALE: 1/8" = 1'-0"

GRAB BARS AT BATHTUBS WITH SEAT AT HEAD OF TUB

4'-0" MINIMUM 4'-0" MINIMUM 2'-0" MIN. 2'-0" MIN. Y= 48" IF THE DOOR HAS A CLOSER Y= 54" IF THE DOOR HAS A CLOSER 60" DIAMETER SPACE 2'-6" 4'-0" PARALLEL APPROACH 5'-0" MIN 3'-0" MIN HAS BOTH A LATCH AND FOWARD APPROACH 4'-0" 2'-6" 4'-0" CLEAR FLOOR SPACE

Y OR 3'-6" MIN 4'-6" MIN.

2'-6" 5'-0" MIN 1'-0" MIN 3'-0" MIN 1'-0" MIN PUSH SIDE A CLOSER NOTE: PULL SIDE Y= 48" MINIMUM IF DOOR NOTE: NOTE: 4'-0" MINIMUM Y OR 4'-0" MIN 5'-0" MINIMUM 18" MIN 3'-6" MIN PULL SIDE PULL SIDE 24" PREFERRED 2'-0" MIN 4'-6" MINIMUM Y OR 3'-6" MIN 4'-0" MINIMUM X PUSH SIDE PUSH SIDE A CLOSER AND A LATCH X=12" IF THE DOOR HAS BOTH NOTE: 3'-6" MINIMUM

30

TWO HINGED DOORS IN SERIES

SCALE: N.T.S. (TYP. CONDITIONS)

31

SCALE: N.T.S. (TYP. CONDITIONS)

FRONT APPROACHES - SWINGING DOORS

32

SCALE: N.T.S. (TYP. CONDITIONS)

LATCH-SIDE APPROACH SWINGING DOORS

33

SCALE: N.T.S. (TYP. CONDITIONS)

HINGE-SIDE APPROACH - SWINGING DOORS

40

SCALE: N.T.S. (TYP. CONDITIONS)

T-SHAPED SPACE FOR 180° TURNS

41

SCALE: N.T.S. (TYP. CONDITIONS)

  • MIN. CLEAR FL. SPACE FOR WHEELCHAIRS

43

SCALE: N.T.S. (TYP. CONDITIONS)

FRONT APPROACH - SLIDING & FOLDING DOORS

42

SCALE: N.T.S. (TYP. CONDITIONS)

LATCH-SIDE APPROACH - SLIDING & FOLDING DOORS

44

SCALE: N.T.S. (TYP. CONDITIONS)

SLIDE-SIDE APPROACH - SLIDING & FOLDING DOORS

METAL THREADED INSERTS TO RECEIVE SCREWS SPECIAL REMOVABLE CABINET FRONT, FLOOR & BASE CARRY FLOOR CABINET, AND WALL FINISHES UNDER & BEHIND REMOVABLE CABINET.

45

SCALE: N.T.S. (TYP. CONDITIONS)

KITCHEN SINK & REMOVABLE BASE CABINET

18" 18" 42" MIN. 42" MIN. 24" 24" 48" MIN. 15" MAX.

ALL PUBLIC HALLS SHALL BE KEPT FREE AND CLEAR OF ALL DUST, DEBRIS, REFUSE, CONSTRUCTION MATERIALS AT ALL TIMES CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER, OR ELECTRICAL SERVICES TO OTHER TENANTS OF THE BUILDING WITHOUT REQUIRED NOTICE INSTALL ALL BARRICADES, SIGNS SCAFFOLDING, TEMPORARY LIGHTING, ETC. AS NEEDED. ALL EXITS AND ACCESS AREAS TO BE MAINTAINED FREE AND CLEAR AT ALL TIMES. GENERAL: ALL WORK TO BE IN ACCORDANCE WITH THE NEW YORK CITY BUILDING CODE, ARTICLE 19 AND REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. FIRE SAFETY:

  • A. ALL BUILDING MATERIALS WHICH ARE STORED AT THE

SITE OR ANY AREA OF THE BUILDING ARE TO BE STORED IN A LOCKED AREA ACCESS TO WHICH TO BE CONTROLLED BY THE OWNER AND OR THE GENERAL CONTRACTOR.

  • B. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION.
  • C. ALL FLAMMABLE MATERIALS TO BE USED AND STORED

IN AN ADEQUATELY VENTILATED SPACE.

  • D. ALL FLAMMABLE MATERIALS TO BE KEPT TIGHTLY

SEALED IN THEIR RESPECTIVE MANUFACTURER'S

  • CONTAINERS. SUCH MATERIALS ARE TO BE KEPT

AWAY FROM HEAT.

  • E. ALL ELECTRICAL POWER TO BE SHUT OFF WHERE

THERE ARE EXPOSED CONDUITS.

  • F. ALL ELECTRICAL POWER IN THE CONSTRUCTION

AREA TO BE SHUT OFF AFTER WORKING HOURS.

  • G. CONTRACTOR TO ENSURE AT ALL TIMES THAT

THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDING OR IN ANY FLAMMABLE GAS USED DURING CONSTRUCTION. DUST CONTROL:

  • A. DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM AND

TO BE CONFINED TO THE IMMEDIATE CONSTRUCTION AREA.

  • B. CONTRACTOR TO ISOLATE CONSTRUCTION AREA FROM

OCCUPIED BUILDING AREA BY MEANS OF TEMPORARY PARTITIONS OR HEAVYWEIGHT DROPCLOTHS.

  • C. DEBRIS, DIRT AND DUST TO BE CLEANED UP AND

CLEARED FROM THE BUILDING SITE PERIODICALLY TO AVOID EXCESSIVE ACCUMULATION. NOISE AFTER HOURS

  • A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO

NORMAL WORKING HOURS; 8 AM TO 5 PM, MONDAY TO FRIDAY EXCEPT LEGAL HOLIDAYS.

  • B. CONTRACTOR MUST OBTAIN WRITTEN PERMISSION

FROM ALL AFFECTED PARTIES TO WORK OTHER THAN REGULAR HOURS. CONSTRUCTION WILL BE CONFINED TO THE APARTMENT INTERIOR AND WILL NOT CREATE DUST, DIRT OR OTHER SUCH INCONVENIENCES TO THE OTHER APARTMENT UNITS WITHIN THE BUILDING THERE WILL BE NO ONE OCCUPYING THE PREMISES TO BE RENOVATED DURING THE COURSE OF CONSTRUCTION. 11. 10. 9. 6. 5. 4. 3. 2. 1. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10.

GENERAL CONSTRUCTION NOTES

TENANT SAFETY NOTES BUILDING DEPARTMENT NOTES

2. 3. 4. 5. 6. 7. 8. 9. ALL WORK SHALL COMPLY WITH ALL APPLICABLE BUILDING, PERFORMANCE AND FIRE SAFETY CODES. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY BUILDING CODE FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS AND THE BEST PRACTICES. ALL EXIT DOORS TO BE INCOMBUSTIBLE ALL WOOD TO BE FIREPROOF, AS PER SECTION C-26-502.6, C-26-1901.3b (3) TABLE 3-5 ALL MATERIALS, ASSEMBLIES AND FORMS, METHODS OF CONSTRUCTION AND SERIES EQUIPMENT SHALL MEET THE FOLLOWING REQUIREMENTS:

  • A. IS ACCEPTABLE FOR USE BY THE NYC BUILDING LAWS
  • B. HAS BEEN ACCEPTED FOR USE BY M.E.A. OR UNDER TEST

METHODS APPROVED FOR USE BY THE COMMISSION OF BUILDINGS.

  • C. HAS BEEN APPROVED FOR USE BY THE BOARD OF

STANDARDS APPEALS. ALL INTERIOR FINISHES SHALL COMPLY WITH THE REQUIREMENTS OF THE NYC BUILDING LAWS, SECTION C26-504.10 REGARDING FLAME SPREAD RATING, SMOKE DENSITY, TOXICITY, ETC.... THE SPACE AROUND CONDUIT PIPES, ETC, PENETRATING CONCRETE SLABS SHALL NOT EXCEED 1 /2" AND SHALL BE PACKED SOLID WITH APPROVED FIRESTOP SEALANT OR APPROVED MATERIAL, AS REQUIRED BY NYC BUILDING LAWS C26-504.5 (24-343). ALL FLOOR/WALL PIPING, ELECTRICAL RO HVAC PENETRATIONS MUST BE FIRESTOPPED. 10. FIRESTOPPING SHALL BE AS REQUIRED BY NYC BUILDING LAWS, SECTION C26-502.7 ALL WOODWORK TO BE FIRE RETARDANT, AS PER NYC BUILDING LAWS, SECTION C26-502.6 BATHROOM FLOOR AREA TO BE MECHANICALLY VENTILATED, AS PER ARTICLE 12, ARTICLE B AND RS-13

SPECIAL & PROGRESS

THE FOLLOWING CONTROLLED INSPECTIONS ARE REQUIRED. ALL CONTROLLED INSPECTIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE ADMINISTRATIVE CODE. ALL CONTROLLED INSPECTIONS SHALL BE PERFORMED BY A LICENSED PROFESSIONAL OR A QUALIFIED PERSON REPRESENTING HIM AND APPROVED BY THE ARCHITECT OF RECORD. 2. FINAL INSPECTION DIRECTIVE 14

SMOKE DETECTOR

EACH DWELLING SHALL BE EQUIPPED WITH AN APPROVED TYPE SMOKE DETECTOR DEVICE RECEIVING PRIMARY POWER FROM THE BUILDING WIRING W/ NO SWITCHES IN THE CIRCUIT OTHER THAN THE OVER CURRENT DEVICE PROTECTING THE BRANCH CIRCUIT AS PER SECT. C26-1705.3. SUCH SMOKE DETECTOR MUST BE EITHER THE IONIZATION CHAMBER TYPE OR THE PHOTOELECTRIC DETECTOR TYPE AS PER SECT. C26-1705.3. ALL SMOKE DETECTORS MUST BE INSTALLED WITHIN 15'-0" OF THE ENTRANCE TO ANY SLEEPING ROOM - WALL OR CLG. MTD. AND INDICATED ON PLAN AS PER NFPD #74-1980. A "CERTIFICATE OF SATISFACTORY INSTALLATION FOR SMOKE DETECTORS" MUST BE FILED WITH THE DIVISION OF CODE ENFORCEMENT HPD 10 DAYS AFTER THE INSTALLATION. 12. 13. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PARTS OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND BUILDING MANAGEMENT. SHUT DOWN OF THE BUIDLING SYSTEMS, IF NECESSARY, SHOULD BE COORDINATED WITH MANAGEMENT AND THE BUIDLING SUPERINTENDENT, AT LEAST 5 DAYS IN ADVANCE THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND DETAIL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY AND DURING THE EXECUTION OF THE WORK. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING THE WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQ'D. FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC.) THE CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING ALL LINES, GRADES AND BENCHMARKS NECESSARY FOR THE PROPER WORK, ALL GIVEN SURVEY DATA SHALL BE VERIFIED BY THE CONTRACTOR. 7. PLUMBING AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS OF REQUIRED SIGN-OFFS. 8. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL THE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE WORK. ALL PIPING AND WIRING SHALL BE REMOVED TO THE POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED. REFER TO SPECIFICATIONS FOR ADDITIONAL CONTRACT REQUIREMENTS. IN THE CASE OF DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT CONDITIONS SHALL APPLY. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. NO CHANNELING OF ANY STRUCTURAL SLAB, DEMISING WALLS AND EXTERIOR WALLS OR PIPE CHASE / SHAFT ENCLOSURE WALLS WILL BE PERMITTED DURING THE COURSE OF ANY WORK. NO REMOVAL OF MASONRY BACK UP MATERIAL AT EXTERIOR OR SHAFT WALLS IS PERMITTED FOR INSTALLATION OF JUNCTION BOXES, ETC. 14. NO REDUCTION IN THE FIRE-RATING OF THE COLUMN ENCLOSURES WILL BE

  • PERMITTED. (IF ANY FIREPROOFING IS DISTURBED IT MUST BE REPLACED.)

15. NO OFFSET OF RISERS (PLUMBING, GAS, ETC.) WILL BE PERMITTED. 16. ACCESS TO RISER SHUT-OFFS MUST BE MAINTAINED. 17. ACCESSIBILITY COMPLIANCE: ALL NEW RENOVATION WORK SHOULD COMPLY WITH THE 2008 NYC BUILDING CODE REQUIREMENTS IN CHAPTER 11, APPENDIX P AND ANSI/ICC A 117.1. 18. ALL PLUMBING WORK WILL BE DONE BY A NEW YORK CITY LICENSED PLUMBER AND ALL ELECTRICAL WORK BY A NEW YORK CITY LICENSED ELECTRICIAN. 19. ALL VENT OPENINGS TO BE SEALED DURING CONSTRUCTION TO PREVENT CARRY OVER OF DUST TO OTHER TENANCIES.

PROJECT INFORMATION

DRAWING LIST 01 G-100.00 GENERAL INFORMATION 02 DM-100.00 DEMO PLAN 03 A-100.00 PROPOSED PLAN 04 A-200.00 DETAILS/ RISER DIAGRAM 05 X-001.00 LANDMARKS 06 X-002.00 LANDMARKS 07 EN-100.00 ENERGY ANALYSIS/ ELECTRICAL PLAN 1. 2. 3. 4.

CARBON MONOXIDE NOTES

CARBON MONOXIDE SHALL COMPLY WITH RS 17-13 AND INSTALLED IN ACCORDANCE WITH RS 17-14. IT SHALL BE PROVIDED IN EVERY DWELLING UNIT WITHIN FIFTEEN FEET OF THE PRIMARY ENTRANCE OF EACH BEDROOM 5.

BLOCK PLAN

SCALE: NTS

ZONING MAP

SCALE: NTS

40-02 44TH STREET SUNNYSIDE QUEENS NY 11104

2008 NYC BUILDING CODE TENANT PROTECTION PLAN

ALL UNITS IN THE BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION 1. ALL REQUIRED RATINGS WILL BE MAINTAINED DURING CONSTRUCTION AND NO TEMPORARY FIRE WALLS WILL BE REQUIRED. ALL WORK IS TO BE CONFINED WITHIN THE APARTMENT. 2. DUST WILL BE KEPT TO A MINIMUM AS WORK WILL BE CONFINED WITHIN THE APARTMENT. CLEAN UP WILL OCCUR AT THE END OF EACH WORK DAY BY THE GENERAL CONSTRACTOR. 3. ALL REQUIRED EGRESS WILL BE MAINTAINED AT ALL TIMES WITH NO OBSTRUCTIONS. NO MODIFICATION TO EGRESS WILL BE REQUIRED FOR THIS PROJECT. 4. ANY EXISTING FIRE PROTECTION ELEMENTS WILL BE MAINTAINED. 5. HEALTH REQUIREMENTS SPECIFIED IN THE 2008 CODE WILL BE COMPLIED WITH. 6. ALL WORK WILL COMPLY WITH ALL APPLICABLE LAWS RELATING TO ASBESTOS AND LEAD PAINT REMOVAL. 7. ALL WORK WILL COMPLY WITH ALL APPLICABLE PORTIONS OF NYC, HMC, AND NYC MDL. 8. NO STRUCTURAL WORK SHALL BE DONE THAT MAY ENDANGER THE OCCUPANTS. 9. NOISE LEVELS WILL COMPLY WITH ALL APPLICABLE ASPECTS OF NOISE CONTROL CODE 10.

INSPECTION NOTES

20. REMOVAL OF CONCRETE FIREPROOFING AT EXISTING STRUCTURAL BEAMS AND COLUMNS IS TO BE AVOIDED. 21. ANY STRUCTURAL STEEL BEAMS AND COLUMN EXPOSED DURING THE OUCRSE OF THE WORK MUST BE FIREPROOFED REGARDLESS OF THEIR HAVING BEEN PREVIOUSLY FIREPROOFED. 22. THE INTERIOR FACE OF ALL EXPOSED EXTERIOR MASONRY WALLS MUST BE DAMP PROOFED PRIOR TO INSTALLATION OF NEW WALL FINISHES. 1. ENERGY CODE COMPLIANCE INSPECTION (TR-8) BLOCK: 182 LOT: 106 BUILDING OCCUPANCY: R4 - RESIDENTIAL, PLANNED COMMUNITY PRESERVATION BUILDING USE: USE GROUP 2 CONSTRUCTION CLASSIFICATION: 1; FIREPROOF ZONING MAP: 9B ZONING DISTRICT: R4 PROJECT ADDRESS: BETH LIEBERMAN GENERAL ZONING INFORMATION SIGNATORY.: BETH LIEBERMAN CLIENT/ SHAREHOLDER: CONTACT: 40-02 44TH STREET QUEENS NY 11104

G-100.00

PLOT PLAN SCALE: NTS

TR-1: SPECIAL & PROCESS INSPECTION ITEMS: TR-8: ENERGY CODE COMPLIANCE INSPECTION ITEMS:

TENANT SAFETY NOTES CONT.

THIS PROPERTY IS NOT WITHIN A SPECIAL FLOOD HAZARD AREA AND NOT SUBJECT TO FLOOD ZONE REGULATIONS

40-02 44TH STREET SUNNYSIDE QUEENS, NY 11104

UPDATED FEMA FLOOD HAZARD DATA FEMA FLOOD HAZARD DATA CURRENTLY AVAILABLE FOR COASTAL AREAS OF NEW YORK AND NEW JERSEY IS PROVIDED BELOW TO HELP YOU UNDERSTAND THE CURRENT FLOOD RISK TO YOUR PROPERTY AND TO GUIDE SANDY RECOVERY AND REBUILDING EFFORTS. NOTE: THIS TOOL PROVIDES FLOOD ZONE AND BASE FLOOD ELEVATION (BFE) INFORMATION FOR AREAS AFFECTED BY COASTAL FLOOD RISK. HOWEVER, RIVERINE FLOOD ZONE INFOMRATION WILL ALSO BE RETURNED BY THE TOOL INCOMMUNITIES WHERE PRELIMINARY FIRMs HAVE BEEN RELEASED.

ATTRIBUTE NAME ATTRIBUTE VALUE WHAT IS THE MOST RECENT FEMO FLOOD HAZARD DATA SOURCE AVAILABLE FOR THIS LOCATION PRELIMINARY FLOOD INSURANCE RATE (FIRM) WHAT IS MY PROPERTY BASE FLOOD ELEVATION (BFE)? N/A WHAT IS MY PROPERTY FLOOD ZONE? N/A WHAT IS MY ESTIMATED GROUND ELEVATION AT THIS LOCATION? 59 - 60 ft (NAVD88)

NEW YORK CITY PRELIMINARY FIRM MAP (2013)

1.

NEW YORK CITY FIRM MAP (2007)

THIS MAP PRINT OUT IS INTENDED FOR INFORMATIONAL PURPOSES. PRELIMINARY FLOOD INSURANCE RATE MAP PANEL COLLECTED FROM FEMA MAPS SERVICE CENTER.

MECHANICAL SYSTEMS 3. 40-02 44TH STREET BLOCK:182 LOT:106 FIRESTOP, DRAFTSTOP, AND FIREBLOCK SYSTEMS 4. LIGHT IN DWELLING UNITS LIGHTING CONTROLS 2. 3. 4. 5. HVAC AND SERVICE WATER HEATING EQUIPMENT HVAC AND SERVICE WATER SYSTEM CONTROLS AIR SEALING AND INSULATION- VISUAL INSPECTION 40-02 44TH STREET QUEENS NY 11104 (347) 731-3247

NO CHANGE OF AREA, USE, OR OCCUPANCY

slide-2
SLIDE 2

116

UP UP DN REF DW UP

101 100 102 103 004

DN UP UP

2

FIRST FLOOR

3

SECOND FLOOR

5

ATTIC

4

ROOF

6

ROOF FRAMING PLAN

7

ATTIC FRAMING PLAN 108 108 110 111 112 113 114 115 116

LEGEND GENERAL NOTES DEMOLITION NOTES DEMO AS PER BC 3306

DEMOLITION PLAN AND ELEVATIONS

DM-100.00

slide-3
SLIDE 3

UP DN

4

ATTIC - CONSTRUCTION 300

UP REF DW UP

101 100 102 103 004 200 201

DN

202 203 204 206

2

FIRST FLOOR

3

SECOND FLOOR

UP DN DN

205

UP DN UP

5

ROOF

GENERAL NOTES SAFETY LEGEND LEGEND CONSTRUCTION NOTES

WINDOW TYPE WINDOW TYPE WINDOW TYPE WINDOW TYPE

A

PTD SOLID CORE DOUBLE PANEL WD DOOR

PROPOSED PLANS

A-100.00

slide-4
SLIDE 4

UP

BATH 1 NOT IN SCOPE

SCALE:1" = 1'-0"

5

40-02 44TH STREET - SANITARY RISER DIAGRAM

GENERAL PLUMBING NOTES:

  • 1. ALL WORK TO BE IN COMPLIANCE W/ NYC DOB REGULATIONS AS WELL AS ALL APPLICABLE STATE AND

LOCAL LAWS.

  • 2. NOTE ALL DIMENSIONS TO BE VERIFIED IN FIELD AND ALL DISCREPENCIES NOTED TO THE ARCHITECT.
  • 3. RISERS TO REMAIN - ALL NEW VALVES TO RISERS AND NEW BRANCH PIPING AS REQUIRED.
  • 4. ANY EXISTING PLUMBING FOR ADJACENT APARMENTS SHALL REMAIN UNDISTURBED.

OTHER FLOORS NOT IN SCOPE 1 1

DETAILS + PLUMBING RISER DIAGRAM

A-200.00

SCALE: 3

4" = 1'0"

ACCESS STAIR SECTION

4

SCALE: 3

4" = 1'0"

ACCESS STAIR ELEVATION

3

SCALE: 3/4" = 1'0"

ACCESS STAIR PLAN

2

SCALE: 3'0" = 1'0"

SEALED AC SLEEVE WITH MATCHED BRICK

1

SCALE: 3

4" = 1'0"

WALL TYPES

6

slide-5
SLIDE 5

5

40-02 44TH ST PROPOSED SECTION

1

40-02 44TH ST FRONT ELEVATION

2

40-02 44TH ST REAR ELEVATION

LANDMARKS SUBMISSION

X-001.00

SCALE: NTS

SOUTH FACING ARIAL VIEW

8

SCALE: NTS

WEST FACING ARIAL VIEW

6

SCALE: NTS

VIEW OF REAR FACADE FROM 44TH STREET

3

SCALE: NTS

VIEW OF REAR FACADE FROM PRIVATE ALLEY

4

SCALE: NTS

VIEW OF FRONT FACADE FROM MEW (SKYLIGHTS NOT VISIBLE)

7

SCALE: NTS

9

VIEW OF FRONT FACADE FROM PUBLIC SIDEWALK (SKYLIGHTS NOT VISIBLE)

slide-6
SLIDE 6

LANDMARKS SUBMISSION

X-002.00

SCALE: NTS

2

SCALE: NTS

1

SCALE: NTS

SKYLIGHT PRECEDENT ON 44TH STREET

3

SKYLIGHT PRECEDENT WITHIN LANDMARKED MEW SKYLIGHT PRECEDENT WITHIN LANDMARKED MEW

SCALE: NTS

40-02 44TH STREET FRONT FACADE VIEW FROM 44TH STREET

5

SCALE: NTS

THROUGH WALL AC PRECEDENT AT NEIGHBOR

4

SCALE: NTS

THROUGH WALL AC PANEL COVER AT NEIGHBOR

6

slide-7
SLIDE 7

UP DN UP UP DN

2

ELECTRICAL PLAN 40-02 44TH 2ND FLOOR

1

ELECTRICAL PLAN 40-02 44TH ATTIC

SAFETY LEGEND LEGEND GENERAL NOTES ENERGY ANALYSIS

EN-100.00

ENERGY ANALYSIS AND PROGRESS INSPECTIONS FOR RESIDENTIAL PROPERTY

APPLICATION TYPE: ALT-2 SCOPE OF WORK: SERVICES PROVIDED TO RENNOVATE AN EXISTING SPACE AND INCLUDE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING WORK, PRIMARILY ON THE INTERIOR OF THE BUILDING. NO ADDITIONAL SQUARE FOOTAGE WILL BE INCREASED IN THE EXISTING SPACE. CLIMATE ZONE: 4 NYCECC CHAPTER 4 (RESIDENTIAL ENERGY EFFICIENCY)

TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, THIS APPLICATION IS IN COMPLIANCE WITH THE NYCECC 2014.

IB MECHANICAL AND PLUMBING INSPECTIONS ITEM DESCRIPTION PROPOSED DESIGN VALUE CODE PRESCRIPTIVE VALUE REQUIRED FREQUENCY (MINIMUM) REFERENCE STANDARD TR-8 INSPECTIONS REQUIRED TR-8 PROGRESS INSPECTION NUMBER AND DESCRIPTION ECC CITATION IC ELECTRICAL POWER AND LIGHTING SYSTEM ITEM DESCRIPTION PROPOSED DESIGN VALUE CODE PRESCRIPTIVE VALUE REQUIRED FREQUENCY (MINIMUM) REFERENCE STANDARD TR-8 INSPECTIONS REQUIRED TR-8 PROGRESS INSPECTION NUMBER AND DESCRIPTION ECC CITATION NEW LIGHTING FIXTURES, LAMPS AND BALLASTS NEW LIGHTING CONTROLS IC2: LIGHTING IN DWELLING UNITS LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE VISUALLY INSPECTED TO VERIFY COMPLIANCE WITH HIGH-EFFICACY REQUIREMENTS 404.2 MORE THAN 50 PERCENT OF THE LAMPS IN ALL COMBINED PERMANENTLY INSTALLED LIGHTING FIXTURES ARE TO BE HIGH-EFFICACY LAMPS. A MINIMUM OF 50 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. PRIOR TO FINAL ELECTRICAL AND CONSTRUCTION INSPECTION APPROVED CONSTRUCTION DOCUMENTS IC2 LIGHTING IN DWELLING UNITS IIC5: LIGHTING IN DWELLING UNITS EACH TYPE OF REQUIRED LIGHTING CONTROLS INCLUDING: OCCUPANT SENSORS, MANUAL INTERIOR LIGHTING CONTROLS, LIGHT-REDUCTION CONTROLS, AUTOMATIC LIGHTING SHUT-OFF, DAYLIGHT ZONE CONTROLS, SLEEPING UNIT CONTROLS, EXTERIOR LIGHTING CONTROLS. SHALL BE VERIFIED BY VISUAL INSPECTION AND TESTED FOR FUNCTIONALITY AND PROPER OPERATION. IIC5 LIGHTING CONTROLS APPROVED CONSTRUCTION DOCUMENTS; INCLUDING SYSTEM NARRATIVES PRIOR TO FINAL ELECTRICAL AND CONSTRUCTION INSPECTION LIGHTING CONTROLS EACH AREA THAT IS REQUIRED TO HAVE A MANUAL LIGTHING CONTROL SHALL ALSO ALLOW THE OCCUPANT TO REDUCE THE CONNECTED LIGHTING LOAD IN AN REASONABLY UNIFORM ILLUMINATION PATTERN BY AT LEAST 50%. 505.2 IA ENVELOP INSPECTIONS

NEW INSULATION AT EXISTING CERTAIN EXSTING INTERIOR WALLS BATT INSULATION

R-VALUE : 5/10

g g R-5 INSULATION CONTINUOUS INSULATION OR R-10 CAVITY INSULATION ON THE INTERIOR AS REQUIRED TO VERIFY CONTINUOUS ENCLOSURE WHILE WALLS, CEILING AND FLOORS ARE OPEN APPROVED CONSTRUCTION DOCUMENTS IB2: INSULATION PLACEMENT AND R- VALUES IA2: INSULATION PLACEMENT AND R-VALVES: INSTALLED INSULATION FOR EACH COMPONENT OF THE CONDITIONED SPACE ENVELOPE AND AT JUNCTIONS BETWEEN COMPONENTS SHALL BE VISUALLY INSPECTED TO ENSURE THAT THE R-VALUES ARE MARKED, THAT SUCH R-VALUES CONFORM TO THE R-VALES IDENTIFIED IN THE CONSTRUCTION DOCUMENTS AND THAT THE INSULATION IS PROPERLY INSTALLED. CERTIFICATION FOR UNMARKED INSULATION SHALL BE SIMILARLY VISUALLY INSPECTED. 303.1, 303.1.1, 303.1.2, 402.1, 402.2, 402.2.2, TABLE 402.4.2 THERMOSTAT PROGRAMMABLE THERMOSTAT. EACH DWELLING UNIT SHALL HAVE AT LEAST ONE THERMOSTAT CAPABLE OF AUTOMATICALLY ADJUSTING THE SPACE TEMPERATURE INSTALL NEW THERMOSTAT PRIOR TO FINAL ELECTRICAL CONSTRUCTION INSPECTION APPROVED CONSTRUCTION DOCUMENTS, INCLUDING CONTROL NARRATIVES IB4: HVAC AND SERVICE WATER HEATING SYSTEM CONTROLS IB4: CONTROLS SYSTEM CONTROLS SHALL BE INSPECTED TO VERIFY THAT EACH DWELLING IS PROVIDED WITH AT LEAST ONE INDIVIDUAL PROGRAMMABLE THERMOSTAT WITH CAPABILITIES AS DESCRIBED IN ECC 403.1.1, AND THAT SUCH CONTROLS ARE SET AND OPERATE AS SPECIFIED IN ECC 403.1.1 CONTROLS FOR SUPPLEMENTARY ELECTRIC- RESISTANCE HEAT PUMPS SHALL BE INSPECTED TO VERIFY THAT SUCH CONTROLS PREVENT SUPPLIMENTAL HEAT OPERATION WHEN THE HEAT PUMP COMPRESSOR CANMEET THE HEATING LOAD. CONTROLS FOR SNOW-AND ICE MELTING SYSTEMS AND POOLS SHALL BE INSPECTED FOR PROPER OPERATION. NOT LESS THAN 20% OR ONE OF EACH CONTROL TYPE, WHICH EVER IS MORE, SHALL BE INSPECTED. 403.1, 403.4, 403.7, 403.8, 403.9, 503, 504 CONTROLS PRIOR TO FINAL ELECTRICAL AND CONSTRUCTION INSPECTION APPROVED CONSTRUCTION DOCUMENTS, INCLUDING CONTROL SYSTEM NARRATIVES IB3 CONTROLS SYSTEM CONTROLS SHALL BE INSPECTED TO VERIFY THAT EACH DWELLING IS PROVIDED WITH AT LEAST ONE INDIVIDUAL PROGRAMMABLE THERMOSTAT WITH CAPABILITIES AS DESCRIBED IN ECC 403.1.1, AND THAT SUCH CONTROLS ARE SET AND OPERATE AS SPECIFIED IN ECC 403.1.1. EQUIPMENT CONTROLS FOR HEATING AND COOLING EQUIPMENT, SET AT CODE PRESCRIBED HEATING AND COOLING TEMPERATURES 403.1, 403.4, 403.7, 403.8, 403.9, 503, 504 PROVIDE CONTROLS FOR HEATING AND COOLING EQUIPMENT PRIOR TO FINAL ELECTRICAL AND CONSTRUCTION INSPECTION IB3: EQUIPMENT HEATING AND COOLING EQUIPMENT SHALL BE VERIFIED BY VISUAL INSPECTION FOR PROPER SIZING. POOL HEATERS AND COVERS SHALL BE VERIFIED BY VISUAL INSPECTION. 403.6 403.7 503 NEW AIR COOLED SPLIT SYSTEM <65 MBH (1)CONDENSER: 2 SEER (1) INDOOR AIR HANDLER CASETTE: 1 SEER (1) INDOOR WALL MOUNTED AIR HANDLER: 1 SEER MINIMUM EFFICIENCY: 6.50 W/W APPROVED CONSTRUCTION DOCUMENTS IB3 EQUIPMENT AS REQUIRED DURING INSTALLATION APPROVED CONSTRUCTION DRAWINGS: NFRC 100 IA3: FENESTRATION U VALUES AND PRODUCT RATINGS IA3: FENESTRATION U-FACTOR AND PRODUCT RATINGS U FACTOR OF INSTALLED FENSTRATION SHALL BE VERIFIED BY VISUAL INSPECTION FOR CONFORMANCE WITH THE U-FACTOR IDENTIFIED IN THE CONSTRUCTION DRAWINGS, EITHER BY VERIFYING THE MANUFACTURER'S NFRC LABELS OR, WHERE NOT LABELED, USING THE RATINGS IN ECC TABLES 303.1.3.(1) AND (2) 403.5, 403.7, 503 SEAL OFF THROUGH WALL AND THROUGH WINDOW AC REMOVE THROUGH WALL AC AND CLOSE OFF WALL PENETRATION MASS WALL R- VALUE : 5/10