HORIBA SEQUOIA JOINT WEBINAR Yogi C. Agrawal, President Sequoia Scientific, Inc., Bellevue, Washington Sequoia Scientific, Inc. (Bellevue, WA) are makers of LISST series field instruments. These are used in coasts, ports, harbors, oceans,
HORIBA ‐ SEQUOIA JOINT WEBINAR Yogi C. Agrawal, President Sequoia Scientific, Inc., Bellevue, Washington
Sequoia Scientific, Inc. (Bellevue, WA) are makers of LISST ‐ series field instruments. These are used in coasts, ports, harbors, oceans, rivers, and in industry. [LISST is a trademark of Sequoia Scientific, Inc.]
Laser Diffraction In ‐ line Holography New: LISST ‐ ABS: 8MHz Acoustic Backscatter
TM instrument is used to study The LISST ‐ SL Velocity, turbidity, sediment concentration and particle size distribution. We find some remarkable results. [LISST is a trademark of Sequoia Scientific, Inc.] (Data courtesy of Chris Curran and Raegan Huffman, USGS Tacoma, WA)
Measure: • Multi ‐ angle scattering; • Optical Transmission Derive: • Particle Size Distribution • Concentration
Lifting Point Underwater Connector Outlet Pitot Tube Intake
• Fish ‐ shaped samplers • Contained a bottle • Sample analyzed in lab P ‐ 61 sampler
• Depth • Optical Transmission • Velocity (from Pitot tube) • Particle Size Distribution • Concentration • Water Temperature • Pump control, and • State of Battery
Topside Control Box B ‐ Reel Pitot tube Intake nozzle
Size Class # 26 27 28 29 30 31 32 Diameter 131 155 183 216 255 302 352 [µm] u * 5.2 5.2 5.3 5.6 6.1 6.9 8.3 [cm/sec] u * = ( D * I * g ) 1/2 ; D = 4m => I =2 x 10 ‐ 4 (USGS reports 3 x 10 ‐ 4 for Cowlitz River)
100 90 2.83 80 70 60 2.57 mg/L 50 1.96 40 30 1.6 20 1.14 0.69 10 0.21 0 9 8 7 6 5 4 3 2 1 Size, phi units
SSC varies x 2 ‐ 3 or more; Xmission does not Strong washload component < ~16 µm SMD increases x 3; VMD increases x 5 Turbidity sensors would miss SSC increase Vertical gradients of coarse particles yields fairly consistent u* estimates Water column mean PSD ~= PSD at half depth Due to Rouse; coarse sediment concentration decays exponentially
Coarse grains in high concentrations can • destroy turbines by abrasion; • Sequoia makes an auto ‐ dilution Laser Diffraction system – LISST Infinite • Real ‐ time data is displayed at Control Room • At hazardous conditions, warning alarms are sounded.
200 ‐ 500 m 75 ‐ 200 m <75 m TOTAL SSC
Linear fit used to predict if concentration will exceed a set value – for warning If critical value (set by operator) is exceeded, alarm will sound Linear fit also predicts when water will clear
8000 25,000 7000 20,000 6000 Concentration (mg/l) Concentration (mg/l) 5000 15,000 4000 120 min interval 10,000 3000 2000 5,000 1000 30 min interval 5 min interval 0 0 25 26 27 28 29 30 31 01 02 03 05 06 07 08 09 May-Jun'11 Oct'11
1200 Mode = 90 mg/l 1000 Number of occurrences 800 600 400 Mean = 235 mg/l 200 0 0 500 1000 1500 2000 Suspended Sediment Concentration (mg/l)
250,000 200,000 Tons of Sediment 150,000 100,000 50,000 Q = 40 m3/s Q = 52 m3/s 0 May Jun Jul Aug Sep Oct Nov Dec Jan Feb Months, 2011-2012
200,000 200-500 µm 75-200µm 2.5-75µm 150,000 Tons of Sediment 100,000 50,000 0 May Jun Jul Aug Sep Oct Nov Dec Jan Feb Months, 2011-2012
LISST ‐ SL and LISST ‐ Infinite instruments Data from a river suggest far superior method for sediment work. Real ‐ time data at a Hydro Power plant warns operators for turbine protection.