Zhaga Book 21 ZHAGA meeting Chicago November 12 th 2019 Freddi - PowerPoint PPT Presentation
Zhaga Book 21 ZHAGA meeting Chicago November 12 th 2019 Freddi Plikun, Martin Creusen Signify Classified - Internal Motivation Provide a plug-and-play, cost-effective and robust solution enabling end- users to replace interoperable linear
Zhaga Book 21 ZHAGA meeting Chicago November 12 th 2019 Freddi Plikun, Martin Creusen
Signify Classified - Internal Motivation • Provide a plug-and-play, cost-effective and robust solution enabling end- users to replace interoperable linear modules. • The interface definition should allow for sufficient options for differentiation at both connector and LED module level. • The proposal aligns nicely with the recent Zhaga move towards interoperability and serviceability of components of LED luminaires. • Moreover, it supports Zhaga in its mission enabling the lighting industry for the upcoming service / circular economy. 2 CONFIDENTIAL 21 November 2019
Signify Classified - Internal Interoperable components Lighting Market size Removing arbitrary variation Lighting market evolution LED penetration Lighting and IoT and in lighting service economy Old Zhaga NEW Zhaga CONFIDENTIAL
Signify Classified - Internal Exchangeable LED-Board Connector 47.303.1001 Basic Product Information
Signify Classified - Internal Connector Design
Signify Classified - Internal Installation
Signify Classified - Internal LED-Board Installation
Signify Classified - Internal Board Removal
Signify Classified - Internal Clip - Board Installation and Removal
Signify Classified - Internal Wiring Wiring: Strip Length: 7-1 mm Strip gauge: 18 AWG (≈0,75mm²) Solid conductors only Electrical ratings: 60V/2A
Signify Classified - Internal Sheetmetal Cutout https://www.youtube.com/watch?v=lCzBN9BNKSs
Signify Classified - Internal 12 CONFIDENTIAL
Signify Classified - Internal 13 CONFIDENTIAL
Signify Classified - Internal Included interfaces to achieve long-term end- user field replaceability and interoperability • Electrical – Between module and connector: LED+, LED- • Mechanical – Contact area (see separate slide on mechanical interface) – Set module dimensions (length, width) – Specific locations and dimensions to attach module to the luminaire • Thermal – Modules are typically self-cooling (e.g. no TIM required) – Define worst case luminaire to check thermal interoperability • Electro-optical – Set basic light technical properties by defining Flux @ I max 14 CONFIDENTIAL 21 November 2019
Signify Classified - Internal Excluded from standardization proposal • Connector - driver interface • Luminaire – connector interface • Wire insertion direction into connector • Mating direction of module into connector 15 CONFIDENTIAL 21 November 2019
Signify Classified - Internal Mechanical interface 16 CONFIDENTIAL 21 November 2019
Signify Classified - Internal Electro-optical interface • Simplified category definition by defining Flux @ I max • OEMs can design-in drivers at < I max current levels. • Fix Lm-ratios for other CCT/CRI levels • Driver voltage is used to correct for increased LED efficacies. 17 CONFIDENTIAL
Signify Classified - Internal Lumen @ I max categories 2ft modules (840) I max Flux at I max Category A 350 mA 2200 Lm Category B 700 mA 4400 Lm 4ft modules (840) I max Flux at I max Category A 700 mA 4400 Lm Category B 1400 mA 8800 Lm 18 CONFIDENTIAL 21 November 2019
Signify Classified - Internal Zhaga book 21 development timeline Jan May Oct Jan April 2018 2018 2019 2019 2020 19 CONFIDENTIAL 21 November 2019