Marc Weber, KIT, Feb. 21, 2012 1
Karlsruhe Institute of Technology: What is it? How does it relate - - PowerPoint PPT Presentation
Karlsruhe Institute of Technology: What is it? How does it relate - - PowerPoint PPT Presentation
Karlsruhe Institute of Technology: What is it? How does it relate to detectors Marc Weber (KIT) Marc Weber, KIT, Feb. 21, 2012 1 Where is KIT ? Central and scenic location in Southern Germany State of Baden-Wrttemberg Close to Black
Marc Weber, KIT, Feb. 21, 2012 2
Where is KIT ?
Central and scenic location in Southern Germany State of Baden-Württemberg Close to Black Forest Close to France 1h by train from Frankfurt airport 2h by car from Switzerland 3h by train from Paris
Marc Weber, KIT, Feb. 21, 2012 3
What is KIT ?
Karlsruhe University + FZK = KIT
Marc Weber, KIT, Feb. 21, 2012 4
Marc Weber, KIT, Feb. 21, 2012 5
KIT in numbers
Marc Weber, KIT, Feb. 21, 2012 6
KIT in HGF programs
Marc Weber, KIT, Feb. 21, 2012 7
Most relevant for detector portfolio are arguably: Physics Electrical engineering and information technology Informatics (“computer science”) Mechanical engineering
Faculties
Marc Weber, KIT, Feb. 21, 2012 8
Of the 157 institutes are arguably most relevant for detectors:
- IEKP, IKP, IPE, ISS/LAS (particle physics, astroparticle physics,
electronics, synchrotron radiation)
- IHE, IMS, IQP, ITIV (high frequency radiation and electronics,
superconducting detectors, quantum photonics, embedded systems)
- IMT, INT (micro and nano technology)
Institutes
Marc Weber, KIT, Feb. 21, 2012 9
A glimpse at physics experiments
Auger, Belle II, CMS, EDELWEISS, KATRIN
Marc Weber, KIT, Feb. 21, 2012 10
A glimpse at technology infrastructure
- Grid Computing Center Karlsruhe (GridKa)
- Tritium Laboratory Karlsruhe (TLK)
- Proton Irradiation Center
- Electron beam lithography for superconducting sensors
- Superconducting magnet test facility (TOSKA)
- Microassembly and -hybridization lab
Marc Weber, KIT, Feb. 21, 2012 11
HEB
Area 2 x 5 μm2 Resolution < 5 ps Channels 1 Power 80 μW Data Rate ~ 100 GS/s (peak) Trigger yes Temperature 77 K Mass
- Radiation hardness
- Ultra-fast YBCO detector
Hot Electron bolometer (IMS) THz antenna
10 20 30 40 50 60 70 80 5 10 15 20 25
Signal amplitude (mV) Time (ns)
0.0 0.1 0.2 0.3 0.4 0.5 5 10 15 20 Signal amplitude (mV) Time (ns)
42 ps
IBias Detector DC block
Wideband LNA (Low Noise Amplifier) Amp
Cryogenic temp (7 – 70K)
Ambient temp
P . Probst et al., APPLIED PHYSICS LETTERS 98, 043504 (2011)
ADC
T/H
Digitalization stage
Marc Weber, KIT, Feb. 21, 2012 12
Non-silicon sensors (FMF and KIT)
Crucial for hard X-rays. Needs: crystal growing and characterization; contacts and flip-chip technology at low temperatures (65K 55 μm pixels)
Silicon is not a great X-ray absorber…
CdTe detector Pictures: M. Fiederle (FMF und KIT)
Marc Weber, KIT, Feb. 21, 2012 13
3D Ultrasonic Computer Tomography (USCT)
- Application: mammography
- 10% of western women develop breast cancer
- High survival probability if detected early
- 3D USCT gives excellent spatial resolution in 3D
- No X-rays
- Cheaper than MRT
Ideal for regular mass screening
3D USCT
Volume 8 liter Resolution < 200 μm Channels 1413 Power < 1.5 kW Data Rate 50 Gb/s Trigger N/A Temperature 30 °C Mass
- Radiation hardness
Marc Weber, KIT, Feb. 21, 2012 14