Fast Ion Loss Detectors for Wave-Particle Interaction Studies Poloidal array of energy and pitch/energy resolving detectors will measure ICRH tail ion fluxes escaping the plasma. D.C. Pace 1 , R.S. Granetz 2 , S.J. Zweben 3 , D.S. Darrow 3 , C.


slide-1
SLIDE 1

Fast Ion Loss Detectors for Wave-Particle Interaction Studies

Shot 1101216005 t = 0.86 s 1 MeV H+, v||/v = 0.1

D.C. Pace1, R.S. Granetz2, S.J. Zweben3, D.S. Darrow3,

  • C. Fiore2, S. Wukitch2,
  • A. Bader2, R. Parker2,

J.H. Irby2, and M. García-Muñoz4

1ORISE, 2MIT, 3PPPL, 4IPP

Poloidal array of energy and pitch/energy resolving detectors will measure ICRH tail ion fluxes escaping the plasma.

Presented at the 2011 Alcator C-Mod Ideas Forum Plasma Science and Fusion Center, MIT January 10 - 12, 2011

slide-2
SLIDE 2
  • Pitch (v||/v) and energy are measured by

imaging scintillator plates

  • Narrow aperture causes scintillator strike position

to be a function of energy and pitch

  • Alfvén eigenmode (AE) analysis

– lost orbits calculated from measurements – simulation using measured AE properties identifies initially confined orbits that are placed on loss orbits due to the interaction*

  • Significant contributor to Alcator C-Mod research

– ICRH efficiency and model validation – perturbation losses: sawteeth, ELMs, AEs – companion to CNPA (cross-constraining) – high-Z wall performance

Phase Space Measurements of Lost Energetic Ions Elucidate Behavior in the Core

Contour represents a NOVA-K calculated TAE with n = 2 and peak δTe/<Te> ≈ 8 x 10-3, DIII-D. D.C. Pace, et al., PPCF, submitted (2010) *M.A. Van Zeeland, et al.,

  • Phys. Plasmas, submitted (2010)

Fast Ion Loss Detectors 2011 Alcator C-Mod Ideas Forum January 10-12, 2011

1.0 1.5 2.0 2.5 R (m)

  • 1.5
  • 1.0
  • 0.5

0.0 0.5 1.0 1.5 z (m) 1.0 1.5 2.0 2.5 R ( ) 5 5 5 Lost Ion Confined Ion FILD

Shot 142111 t = 570 ms

slide-3
SLIDE 3
  • Energy selection is determined

by gold film thickness

  • Construct/install five units

during 2011 vent

  • Pitch/energy resolving unit to

follow (test on S3)

Fast Ion Loss Detectors 2011 Alcator C-Mod Ideas Forum January 10-12, 2011

Scintillator Detectors are Sampled at 2 MHz, Capable of Resolving High Frequency MHD Activity

Film Scintillator Glass Probe Shaft Mirror Lens Fiber Optic Ion Impacts Film Size ~ 1 cm

Energy Resolving Unit (shield, aperture not shown)

  • Orbit modeling indicates LH-limiter as the

ideal mounting position (facing B-port)

  • Up-to-date status information,